Skip to content

Condition Monitoring Measurements IDs

Legacy documentation

This page is preserved from the previous knowledge base and describes older Treon products and manual configuration workflows. It is kept for reference and is not maintained against current Treon Connect releases.

Each measurement ID of a Treon Industrial Node corresponds with a different set of settings.

Measurement ID 0 standard 3-axial KPI measurement
Measurement ID 1 standard 3-axial FFT measurement with low and high filters
Measurement ID 2 1-axis FFT measurement, 2-740Hz filter (higher resolution)
Measurement ID 3 1-axis FFT measurement, 2-494Hz filter (higher resolution)
Measurement ID 4 3-axial waveform (raw data) measurement
Measurement ID 5 3-axial waveform (raw data) measurement, low data sample count
Measurement ID 6 1-axial waveform (raw data) measurement
Measurement ID 7 1-axial waveform (raw data) measurement, low data sample count

Please use Measurement ID 0 as a standard. Specifically raw data measurements can be problematic in some mesh network where one node forwards data from several other nodes to the gateway, or in cases when the SIM network connection of the gateway is very low.

The settings in detail:

Measurement ID 0

**| | | |---|---| | G-range | 4G | | Data Sample Count | 26667 | | Axis | Triaxial | | Calculation ID 0 | | | Features | RMS (Acceleration) | | | P2P & Z2P (Acceleration) | | | Crest Factor | | | Kurtosis | | Filter | Low pass, - 6666,7 Hz | | Calculation ID 1 | | | Features | RMS (Velocity) | | | P2P & Z2P (Velocity) | | Filter | Band pass, 10,0 Hz - 1000,0 Hz |

Measurement ID 1

**| | | |---|---| | G-range | 4G | | Data Sample Count | 32768 | | Axis | Triaxial | | Calculation ID 2 | | | Features | Spectrum (FFT) | | Filter | Low pass, - 6666,7 Hz | | Calculation ID 3 | | | Features | Spectrum (FFT) | | Filter | Band pass, 2,0 Hz - 1333,5 Hz |

Measurement ID 2

****| | | |---|---| | G-range | 4G | | Data Sample Count | 57344 | | Axis | Vertical | | Calculation ID 4 | | | Features | Spectrum (FFT) | | Filter | Band pass, 2,0 Hz - 740,0 Hz |

Measurement ID 3

****| | | |---|---| | G-range | 4G | | Data Sample Count | 90112 | | Axis | Vertical | | Calculation ID 5 | | | Features | Spectrum (FFT) | | Filter | Band pass, 2,0 Hz - 494,0 Hz |

Measurement ID 4

****| | | |---|---| | G-range | 4G | | Data Sample Count | 36864 | | Axis | Triaxial | | Calculation ID 10 | | | Features | Waveform |

Measurement ID 5

****| | | |---|---| | G-range | 4G | | Data Sample Count | 18432 | | Axis | Triaxial | | Calculation ID 10 | | | Features | Waveform |

Measurement ID 6

****| | | |---|---| | G-range | 4G | | Data Sample Count | 110592 | | Axis | Vertical | | Calculation ID 10 | | | Features | Waveform |

Measurement ID 7

****| | | |---|---| | G-range | 4G | | Data Sample Count | 26667 | | Axis | Vertical | | Calculation ID 10 | | | Features | Waveform |