default

Treon Industrial Node 6 Default Configuration

This article shows the default configuration of the Treon Industrial Node 6. Fig.: Treon Industrial Node 6 DM Model.  Timer Parameters Time ON/OFF Measurement Selection Timer 1 1h ON 0 Timer 2 6h ON 1 Timer 3 24h OFF 2 and 3 Status Interval 3h ON none  Measurement Parameters Measurement ID 0 1 2 3 Default Axis 3 3 3 x-axis All G-Range 4 4 4 4 4 Sample Amount 36864 36864 36864 68268 110592 Calculations 1 and 3 2 and 4 5 6 0  Calculation Parameters CalcID 1 2 3 4 5 6 Default Features v-RMS, v-PEAK, v-P2P, Clipping detect LOW FFT, Clipping detect a-RMS, a-PEAK, a-P2P, Kurtosis, Crest, Clipping detect HIGH FFT, Clipping detect Raw data Raw data FFT, aRMS, aPEAK Low cut-off 10 10 no filter no filter no filter High cut-off 1000 1333 no filter no filter no filter Decimation 9 0 1 Averages 0 9 0 Overlap % 0 0 0 Window Hanning Hanning Hanning Lines of resolution 1600 1600 2048 FFT format Variable Variable Auto (no variable)  Wakeup Parameters Default Feature Enable OFF Wake-up G-range 4G Wake-up threshold 8 Wake-up Action Delay 30s Wake-up Blank-time 900s Action measurement ON Action Indication OFF Action LED ON Measurements to be triggered 1  

Treon Asset Node

This article shows the default configuration of the Treon Asset Node.   ID Description Reporting Interval minutes Temperature Shock BT Beacon Status Alert Alert Level Status 0 All Off OFF OFF OFF OFF OFF OFF 1 Test profile 5 Min set OFF ON OFF ON 2 Temperature monitoring 15 Full set OFF OFF OFF OFF 3 Temperature monitoring 60 Full set OFF OFF OFF OFF 4 Freezer monitoring 15 Full set < -31 or > -15 Min set in 5 min interval OFF OFF OFF 5 Freezer monitoring 60 Full set < -31 or > -15 Min set in 5 min interval OFF OFF OFF 6 Refrigerator monitoring 15 Full set < 0c or >8c Min set in 5 min interval OFF OFF OFF 7 Refrigerator monitoring 60 Full set < 0c or >8c Min set in 5 min interval OFF OFF OFF 8 Shock Monitoring (low) OFF OFF OFF ON >=15G OFF 9 Shock Monitoring (low) 30 Full set OFF ON >=15G OFF 10 Environmental and Shock monitoring 15 Full set OFF ON >=15G OFF 11 Environmental and Shock monitoring 60 Full set OFF ON >=15G OFF 12 Refrigerator and Shock monitoring 15 Full set < 0c or >8c Min set in 5 min interval ON >=15G OFF 13 Refrigerator and Shock monitoring 60 Full set < 0c or >8c Min set in 5 min interval ON >=15G OFF 14 Intrusion Alert 30 OFF OFF OFF OFF OFF 15 Shock Monitoring (high) OFF OFF OFF ON >=40G OFF 16 Shock Monitoring (high) 30 Full set OFF ON >=40G OFF 17 Rapid light 5 OFF OFF OFF OFF OFF 18 Refrigerator monitoring (meat and fish) 15 Full set < 0c or >4c Min set in 5 min interval OFF OFF OFF 19 Refrigerator monitoring (meat and fish) 60 Full set < 0c or >4c Min set in 5 min interval OFF OFF OFF Notes:

Default Configuration