default

Treon Industrial Node 6 Default Configuration

This article shows the default configuration of the Treon Industrial Node 6. Fig.: Treon Industrial Node 6 DM Model.  Timer Parameters Time ON/OFF Measurement Selection Timer 1 1h ON 0 Timer 2 6h ON 1 Timer 3 24h OFF 2 and 3 Status Interval 3h ON none  Measurement Parameters Measurement ID 0 1 2 3 Default Axis 3 3 3 x-axis All G-Range 4 4 4 4 4 Sample Amount 36864 36864 36864 68268 110592 Calculations 1 and 3 2 and 4 5 6 0  Calculation Parameters CalcID 1 2 3 4 5 6 Default Features v-RMS, v-PEAK, v-P2P, Clipping detect LOW FFT, Clipping detect a-RMS, a-PEAK, a-P2P, Kurtosis, Crest, Clipping detect HIGH FFT, Clipping detect Raw data Raw data FFT, aRMS, aPEAK Low cut-off 10 10 no filter no filter no filter High cut-off 1000 1333 no filter no filter no filter Decimation 9 0 1 Averages 0 9 0 Overlap % 0 0 0 Window Hanning Hanning Hanning Lines of resolution 1600 1600 2048 FFT format Variable Variable Auto (no variable)  Wakeup Parameters Default Feature Enable OFF OFF Wake-up G-range 4G 4G Wake-up threshold 2 8 Wake-up Action Delay 5s 30s Wake-up Blank-time 3600s 900s Action measurement ON ON Action Indication ON OFF Action LED OFF ON Measurements to be triggered 1 1  Treon Support You still have questions?

Default Configuration

Treon Asset Node

This article shows the default configuration of the Treon Asset Node.   ID Description Reporting Interval minutes Temperature Shock BT Beacon Status Alert Alert Level Status 0 All Off OFF OFF OFF OFF OFF OFF 1 Test profile 5 Min set OFF ON OFF ON 2 Temperature monitoring 15 Full set OFF OFF OFF OFF 3 Temperature monitoring 60 Full set OFF OFF OFF OFF 4 Freezer monitoring 15 Full set < -31 or > -15 Min set in 5 min interval OFF OFF OFF 5 Freezer monitoring 60 Full set < -31 or > -15 Min set in 5 min interval OFF OFF OFF 6 Refrigerator monitoring 15 Full set < 0c or >8c Min set in 5 min interval OFF OFF OFF 7 Refrigerator monitoring 60 Full set < 0c or >8c Min set in 5 min interval OFF OFF OFF 8 Shock Monitoring (low) OFF OFF OFF ON >=15G OFF 9 Shock Monitoring (low) 30 Full set OFF ON >=15G OFF 10 Environmental and Shock monitoring 15 Full set OFF ON >=15G OFF 11 Environmental and Shock monitoring 60 Full set OFF ON >=15G OFF 12 Refrigerator and Shock monitoring 15 Full set < 0c or >8c Min set in 5 min interval ON >=15G OFF 13 Refrigerator and Shock monitoring 60 Full set < 0c or >8c Min set in 5 min interval ON >=15G OFF 14 Intrusion Alert 30 OFF OFF OFF OFF OFF 15 Shock Monitoring (high) OFF OFF OFF ON >=40G OFF 16 Shock Monitoring (high) 30 Full set OFF ON >=40G OFF 17 Rapid light 5 OFF OFF OFF OFF OFF 18 Refrigerator monitoring (meat and fish) 15 Full set < 0c or >4c Min set in 5 min interval OFF OFF OFF 19 Refrigerator monitoring (meat and fish) 60 Full set < 0c or >4c Min set in 5 min interval OFF OFF OFF Notes: