Activating the Mesh Network

Introduction Before and after the deployment of a mesh network, it is important to test and troubleshoot common issues in deployment.  Testing the Network Before you install the physical devices at the deployment site, first perform a dry-run of the system to test if the network runs.

Network Connectivity

Network Connectivity

Shipment Details

 Container measurement data:

Treon Gateway In Protective Enclosure - Unpacking & Installation

What’s in the box The sales box of the Treon Gateway in Protective Enclosure contains the following: Treon Gateway in Protective Enclosure Documentation Here is a video showing the unboxing of the Treon Condition Monitoring Starter Kit with a Treon Gateway In Protected Enclosure and Treon Industrial Nodes 6:

Treon Gateway In Protective Enclosure - Unpacking & Installation

What’s in the box The sales box of the Treon Gateway in Protective Enclosure contains the following: Treon Gateway in Protective Enclosure Documentation Here is a video showing the unboxing of the Treon Condition Monitoring Starter Kit with a Treon Gateway In Protected Enclosure and Treon Industrial Nodes 6:

Connect your Treon Gateway

Introduction Your Treon Connect Test Kit gateway typically comes equipped with a SIM card operational in your country. Additionally, all Treon Gateways can be connected to the the internet via Ethernet connection or Wi-Fi.

Troubleshooting - Treon Gateways

No connection via SIM card If the Treon Gateway has a SIM card in its SIM card slot but does not connect to the network (indicated by a red status light), there are several possible root causes.

Treon Industrial Node 6 Default Configuration

This article shows the default configuration of the Treon Industrial Node 6. Fig.: Treon Industrial Node 6 DM Model.  Timer Parameters Time ON/OFF Measurement Selection Timer 1 1h ON 0 Timer 2 6h ON 1 Timer 3 24h OFF 2 and 3 Status Interval 3h ON none  Measurement Parameters Measurement ID 0 1 2 3 Default Axis 3 3 3 x-axis All G-Range 4 4 4 4 4 Sample Amount 36864 36864 36864 68268 110592 Calculations 1 and 3 2 and 4 5 6 0  Calculation Parameters CalcID 1 2 3 4 5 6 Default Features v-RMS, v-PEAK, v-P2P, Clipping detect LOW FFT, Clipping detect a-RMS, a-PEAK, a-P2P, Kurtosis, Crest, Clipping detect HIGH FFT, Clipping detect Raw data Raw data FFT, aRMS, aPEAK Low cut-off 10 10 no filter no filter no filter High cut-off 1000 1333 no filter no filter no filter Decimation 9 0 1 Averages 0 9 0 Overlap % 0 0 0 Window Hanning Hanning Hanning Lines of resolution 1600 1600 2048 FFT format Variable Variable Auto (no variable)  Wakeup Parameters Default Feature Enable OFF Wake-up G-range 4G Wake-up threshold 8 Wake-up Action Delay 30s Wake-up Blank-time 900s Action measurement ON Action Indication OFF Action LED ON Measurements to be triggered 1  

Update your Treon Industrial Nodes