beginner

Connecting to the Treon Gateway

Contact Treon

Treon Gateway Ethernet Connection

Ethernet connection Treon Gateway & Treon Gateway 2 You can establish an ethernet connection simply by attaching an ethernet cable to the Treon Gateway (QuickStart Guide item D). Ethernet connection Treon Gateway in Protective Enclosure For establishing an ethernet connection with the Treon Gateway in Protective Enclosure, you need to open up the enclosure to gain access.

Installation Treon Industrial Node and Industrial Node 6

Activating the Mesh Network

Introduction Before and after the deployment of a mesh network, it is important to test and troubleshoot common issues in deployment.  Testing the Network Before you install the physical devices at the deployment site, first perform a dry-run of the system to test if the network runs.

Network Connectivity

Troubleshooting - Treon Gateway

The Treon Gateway cannot connect via SIM card If the Treon Gateway has a SIM card in its SIM card slot but does not connect to the network (indicated by a red status light), there are several possible root causes.

Treon Gateway In Protective Enclosure - Unpacking & Installation

What’s in the box The sales box of the Treon Gateway in Protective Enclosure contains the following: Treon Gateway in Protective Enclosure Documentation Here is a video showing the unboxing of the Treon Condition Monitoring Starter Kit with a Treon Gateway In Protected Enclosure and Treon Industrial Nodes 6:

Treon Industrial Node 6 Default Configuration

This article shows the default configuration of the Treon Industrial Node 6. Fig.: Treon Industrial Node 6 DM Model.  Timer Parameters Time ON/OFF Measurement Selection Timer 1 1h ON 0 Timer 2 6h ON 1 Timer 3 24h OFF 2 and 3 Status Interval 3h ON none  Measurement Parameters Measurement ID 0 1 2 3 Default Axis 3 3 3 x-axis All G-Range 4 4 4 4 4 Sample Amount 36864 36864 36864 68268 110592 Calculations 1 and 3 2 and 4 5 6 0  Calculation Parameters CalcID 1 2 3 4 5 6 Default Features v-RMS, v-PEAK, v-P2P, Clipping detect LOW FFT, Clipping detect a-RMS, a-PEAK, a-P2P, Kurtosis, Crest, Clipping detect HIGH FFT, Clipping detect Raw data Raw data FFT, aRMS, aPEAK Low cut-off 10 10 no filter no filter no filter High cut-off 1000 1333 no filter no filter no filter Decimation 9 0 1 Averages 0 9 0 Overlap % 0 0 0 Window Hanning Hanning Hanning Lines of resolution 1600 1600 2048 FFT format Variable Variable Auto (no variable)  Wakeup Parameters Default Feature Enable OFF Wake-up G-range 4G Wake-up threshold 8 Wake-up Action Delay 30s Wake-up Blank-time 900s Action measurement ON Action Indication OFF Action LED ON Measurements to be triggered 1  Treon Support You still have questions?

Update your Treon Industrial Nodes