Troubleshooting - Treon Gateways

No connection via SIM card If the Treon Gateway has a SIM card in its SIM card slot but does not connect to the network (indicated by a red status light), there are several possible root causes.

Treon Industrial Node 6 Default Configuration

This article shows the default configuration of the Treon Industrial Node 6. Fig.: Treon Industrial Node 6 DM Model.   Please note: The configuration shown here is valid for FW version 6.

Treon Industrial Node 6 old Default Configuration

This article shows the default configuration of the Treon Industrial Node 6 before FW 6.17 Fig.: Treon Industrial Node 6 DM Model.  Timer Parameters Time ON/OFF Measurement Selection Timer 1 1h ON 0 Timer 2 6h ON 1 Timer 3 24h OFF 2 and 3 Status Interval 3h ON none  Measurement Parameters Measurement ID 0 1 2 3 Default Axis 3 3 3 x-axis All G-Range 4 4 4 4 4 Sample Amount 36864 36864 36864 68268 110592 Calculations 1 and 3 2 and 4 5 6 0  Calculation Parameters CalcID 1 2 3 4 5 6 Default Features v-RMS, v-PEAK, v-P2P, Clipping detect LOW FFT, Clipping detect a-RMS, a-PEAK, a-P2P, Kurtosis, Crest, Clipping detect HIGH FFT, Clipping detect Raw data Raw data FFT, aRMS, aPEAK Low cut-off 10 10 no filter no filter no filter High cut-off 1000 1333 no filter no filter no filter Decimation 9 0 1 Averages 0 9 0 Overlap % 0 0 0 Window Hanning Hanning Hanning Lines of resolution 1600 1600 2048 FFT format Variable Variable Auto (no variable)  Wakeup Parameters Default Feature Enable OFF Wake-up G-range 4G Wake-up threshold 8 Wake-up Action Delay 30s Wake-up Blank-time 900s Action measurement ON Action Indication OFF Action LED ON Measurements to be triggered 1  

Update your Treon Industrial Nodes

Update your Treon Industrial Nodes

Installation without Adapter

Introduction For this installation method, the Treon Industrial Node is directly attached to the machine surface. This minimizes the vibration transmission route for best measurement quality. Manual alignment of the Industrial Node is not possible with this installation method.

Treon Connect App UI Navigation

First log-in After starting the Treon Connect app for the first time, you are asked to enter the name of your Treon Connect instance. Enter the link you have received and press SELECT.

Condition Monitoring Measurements

Condition Monitoring Assets

The Treon Connect Condition Monitoring app let’s you analyse the condition monitoring data from your assets, trigger individual measurements, and set up alerts and warnings. The Assets tab provides a full list of condition monitoring assets.

How to Commission Sensors

The Treon Industrial Sensor C is a wireless battery- operated sensor device for collecting condition monitoring data of industrial equipment. When the device is powered on and provisioned, it starts automatically to measure and transmit data.